Heads can be selected from the plan view and then their parameters changed by pressing and holding
the Group, Position, Colour or Beam buttons. When the programmer settingHighlight defaults beam
and colour is enabled, any heads selected will have their dimmer set to 100% in open white.
14.7 Time-code support
MagicQ supports time-code for running sequences of Cues in a specific timed sequence rather than with
individual fade times. Cues can be set to time-code by changing the Halt field in the Cue Stack
window.
Time code can be triggered from an external SMPTE time-code source using the optional ChamSys
MIDI/SMPTE module, or it can run from the internal time-code source. To control a Cue Stack using
external time-code set theExternal time-code” option in the Cue Stack options.
When a Cue Stack that contains time-code cues is activated the time code takes control of the Cue Stack
and each Cue executes at the time-code specified. For Internally generated time-code, activating the
Cue Stack starts the time-code at 0/0/0. For external time-code the time-code will be read from the
external module.
It is possible for the console to learn the timing live. Set the steps in the Cue Stack to time-code. Then
release the Cue Stack, and in the Cue Stack window, press SHIFT and RECORD TC. Now press the
GO button for the Cue Stack. MagicQ starts the time-code running at 0/0/0 and each time you press
GO it moves to the next Cue whilst recording the current time-code into the Wait fields. At the end of
the Cue Stack, press RELEASE to exit the time-code record mode.
Time-code values can be edited individually and can be set in the format 0/0/0.00. The + and
operators can be used to add or subtract times to the time-code times for one or more cues. This is
useful for changing the absolute times of a Cue Stack whilst maintaining the relative times between
Cues.
14.8 Scheduled Events
MagicQ now supports timed events. Any Cue in a Cue Stack can be set to trigger based on a scheduled
event rather than following on from the previous Cue. This enables time of day and date based events
to be run automatically.
To use this feature, set the Halt field in the Cue Stack Window to “Sched. Then enter the time in the
Wait field. You can enter a full time:
19/30/5 for 19 hours 30 minutes and 5 seconds
or
*/10/0 to have the event occur every hour at 10 minutes past the hour
or
*/*/0 for every minute
It is also possible to set dates. Dates are entered into the macro field starting with Z and ending with Z.
For example to have an event on the 24 December 2005 enter:
Z24/10/2005Z
Vista de pagina 99